DL20090 Series
Ultra-high performance single-phase filter DL20090 Multistage ac/dc EMC filters with excellent attenuation performance
Product Overview
Downloads
DL20090 Series
Key words:
DL20090 Series
Classification:
Product Description
| Article | Rated Current @40℃ (A) | Leakage current IEC60939 (mA) | Power Loss (W) | Inductance L(mH) | Capacitance | Resistance (kΩ) | Input/Output connections (Nm) | ||
| Cx (µF) | Cy1(nF) | Cy2(nF) | |||||||
| DL20090-1-06 | 1 | 0.45 | 1.8 | 20 | 0.22 | 2.2 | 1.0 | 1000 | |
| DL20090-3-06 | 3 | 0.45 | 3.7 | 14 | 0.33 | 2.2 | 1.0 | 470 | |
| DL20090-6-06 | 6 | 0.61 | 7.1 | 8 | 0.47 | 3.3 | 1.0 | 220 | |
| DL20090-10-06 | 10 | 0.61 | 8.4 | 8 | 0.47 | 3.3 | 1.0 | 220 | |
| DL20090-16-06 | 16 | 0.93 | 10.7 | 4 | 1.0 | 10 | 1.0 | 220 | |
| DL20090-20-06 | 20 | 0.93 | 8.2 | 2.7 | 1.0 | 10 | 1.0 | 220 | |
| DL20090-20-08 | 20 | 0.93 | 8.2 | 2.7 | 1.0 | 10 | 1.0 | 220 | Threaded stud bolt |
| DL20090-30-08 | 30 | 0.93 | 10.1 | 1.28 | 1.0 | 10 | 1.0 | 220 | Threaded stud bolt |
Features and Benefits
▪ The design of DL20090 two-stage filter facilitates quick installation
▪ The DL20090N version does not have a ground capacitance and complies with the ME (Medical Equipment) 1MOP standard of IEC 60601-1. The DL20090S version has a low ground capacitance value and is suitable for safety critical applications that require low leakage current
▪ All filters provide a special conduction attenuation performance, and the choke coil DL20090 two-stage filter based on high permeability magnetic core material is designed for high noise applications that require excellent filtering performance.
▪ Various terminal options allow you to choose the desired connection method
▪ The DL20090 filter also has a corresponding single-stage filtering version (DL20030 series)
▪ The higher inductance provides higher attenuation performance, with the same external dimensions as the DL20060 and DL20080 series.
Typical Applications
▪ Electrical and electronic equipment
▪ Consumer goods
▪ Household equipment
▪ Building automation
▪ Idustrial applications
▪ Mechanical
▪ Medical equipment
▪ Electronic data processing equipment
▪ Office automation and data communication equipment
▪ Various complex applications that require good filtering performance
Technical Specifications
Maximum continuous operating voltage: 250 VAC, 50/60 Hz
Rated current: 1 to 30 A @ 40 ° C
Operating frequency: DC to 400 Hz
Voltage withstand test: P ->N 1100 VDC for 2 seconds; P –> PE 2250 VDC for 2 sec
Temperature range (operation and storage) -25 ° C to+100 ° C (25/100/21)
Typical electrical schematic

Get Product Inquiry