Product Description
| Article | Rated Current @40℃ (A) | Leakage current IEC60939 (mA) | Power Loss (W) | Inductance L(mH) | Capacitance | Resistanc (kΩ) | Input/Output connections | |
| Cx (µF) |
Cy1(nF) | |||||||
| DL20070-1-06 | 1 | 0.66 | 2.4 | 22 | 0.33 | 4.7 | 1000 | |
| DL20070-3-06 | 3 | 0.66 | 2.2 | 9.8 | 0.47 | 4.7 | 470 | |
| DL20070-6-06 | 6 | 0.66 | 3.2 | 7.8 | 1.0 | 4.7 | 220 | |
| DL20070-10-06 | 10 | 0.66 | 9.1 | 4.5 | 1.0 | 4.7 | 220 | |
| DL20070-12-06 | 12 | 0.66 | 13.1 | 3.25 | 1.0 | 4.7 | 220 | |
| DL20070-16-06 | 16 | 0.66 | 9.6 | 2.8 | 1.0 | 4.7 | 1000 | |
| DL20070-16-08 | 16 | 0.66 | 9.6 | 2.8 | 1.0 | 4.7 | 220 | Threaded stud bolt |
| DL20070-25-08 | 25 | 0.66 | 11.6 | 2 | 2.2 | 4.7 | 220 | Threaded stud bolt |
| DL20070-36-08 | 36 | 0.66 | 13.1 | 1.23 | 2.2 | 10 | 220 | Threaded stud bolt |
Features and Benefits
▪ The design of DL20070 two-stage filter facilitates quick installation
▪ The DL20070N version does not have a ground capacitor and complies with the ME (Medical Equipment) 1MOP standard of IEC 60601-1
▪ DL20070S version has a low ground capacitance value and is suitable for safety critical applications that require low leakage current
▪ The DL20070 two-stage filter is designed for high-frequency attenuation
▪ All filters provide high conduction attenuation performance.
▪ Various terminal options allow you to choose the desired connection method
▪ The DL20070 filter can also have a corresponding single-stage filtering version (DL20030 series) for use
▪ The DL20070 filter also has a corresponding differential mode inductor version (DL20080 series)
Typical Applications
▪ Electrical and electronic equipment
▪ Consumer goods
▪ Household equipment
▪ Building automation
▪ Industrial applications
▪ Medical equipment
▪ Electronic data processing equipment
▪ Office automation and data communication equipment
▪ Various complex applications that require high filtering performance
▪ Single phase motor drive
Technical Specifications
Maximum continuous operating voltage: 250 VAC, 50/60 Hz
Rated current: 1 to 36 A @ 40°C
Operating frequency: 50/60 Hz
Voltage withstand test: P –> N 1100 VDC for 2 sec ; P –> PE 2250 VDC for 2 sec
Temperature range (operation and storage) ﹣25 °C to +100 °C (25/100/21)
Typical electrical schematic