DL20070 Series

High CM, DM & HF Attenuation AC/DC EMI filter

Product Overview

Downloads

DL20070 Series

Universal AC/DC EMI filter with high attenuation performance The rated current is 1 to 36 amps High differential mode and common mode attenuation High frequency attenuation Optional medical version (N-type) Optional security version (S-type)

Key words:

DL20070 Series

Product Description

Article

Rated Current

@40℃ (A)

Leakage current IEC60939 (mA)Power Loss (W)Inductance L(mH)Capacitance

Resistanc

(kΩ)

Input/Output connections 
Cx (µF)

 

Cy1(nF)   

DL20070-1-0610.662.4220.334.71000 
DL20070-3-0630.662.29.80.474.7470 
DL20070-6-0660.663.27.81.04.7220 
DL20070-10-06100.669.14.51.04.7220 
DL20070-12-06120.6613.13.251.04.7220 
DL20070-16-06160.669.62.81.04.71000 
DL20070-16-08160.669.62.81.04.7220Threaded stud bolt
DL20070-25-08250.6611.622.24.7220Threaded stud bolt
DL20070-36-08360.6613.11.232.210220Threaded stud bolt

 

Features and Benefits

▪ The design of DL20070 two-stage filter facilitates quick installation

▪ The DL20070N version does not have a ground capacitor and complies with the ME (Medical Equipment) 1MOP standard of IEC 60601-1

▪ DL20070S version has a low ground capacitance value and is suitable for safety critical applications that require low leakage current

▪ The DL20070 two-stage filter is designed for high-frequency attenuation

▪ All filters provide high conduction attenuation performance.

▪ Various terminal options allow you to choose the desired connection method

▪ The DL20070 filter can also have a corresponding single-stage filtering version (DL20030 series) for use

▪ The DL20070 filter also has a corresponding differential mode inductor version (DL20080 series)

 

Typical Applications

▪ Electrical and electronic equipment    
▪ Consumer goods    
▪ Household equipment     
▪ Building automation    
▪ Industrial applications    
▪ Medical equipment    
▪ Electronic data processing equipment    
▪ Office automation and data communication equipment    
▪ Various complex applications that require high filtering performance    
▪ Single phase motor drive 
 

Technical Specifications

Maximum continuous operating voltage: 250 VAC, 50/60 Hz

Rated current: 1 to 36 A @ 40°C

Operating frequency: 50/60 Hz

Voltage withstand test: P –> N 1100 VDC for 2 sec ; P –> PE 2250 VDC for 2 sec 

Temperature range (operation and storage) ﹣25 °C to +100 °C (25/100/21)

 

Typical electrical schematic

Get Product Inquiry

Please fill in the form below, our staff will contact you within 24 hours and solve your problem as soon as possible.